  • Intelligent TDL Gateways

    Curtiss-Wright Defense Solutions

    Military organizations around the world rely heavily on tactical data links (TDL) to share mission-critical information securely and reliably among air, ground, and sea platforms. Because different devices use different data links for communications, a highly sophisticated TDL gateway is needed to translate information across the various link types. Equipped with an intuitive user interface displayed in an easy-to-understand format, Curtiss-Wright’s patented multi-link gateway solutions simplify how platforms communicate through different standards and data link protocols.

  • Development Switch

    TTESwitch Lab Space - TTTech Computertechnik AG

    The TTESwitch Lab Space supports laboratory testing efforts of Time-Triggered Ethernet applications; user development costs can be reduced by using the internal TTESwitch Controller HiRel ASIC that is also used in flight equipment. With advanced features like speeds of up to 1 Gbit/s, flexible physical layer configuration and three supported traffic classes, it is the optimal switching solution for a large variety of application areas. TTEthernet is a fault-tolerant, real-time communication protocol for safety-relevant systems integrating Ethernet and TTEthernet data flows onto one physical infrastructure.

  • High Power DC Power Supply

    Maynuo Electronic Co.,Ltd

    *Low ripple and low noise*High resolution and accuracy (0.1mV/0.01mA)*Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter*Supporting high-accuracy and dynamic programming output*High-luminance VFD screen with two lines& four channels display*Intellegent fan system fan will be automatically initiated according to the temperature*Supporting remote voltage compensation and multidata storage*Supporting external trigger input and output*Power-on-self-test, software calibration and standard rack mount*Using standard SCPI protocol*Communication mode: RS232/RS485/USB.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Analog Input Module

    ND-6017 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-422/RS-485 Repeater

    ND-6510 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Relay Output & Digital Input Module

    ND-6060 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Digital Ethernet Power Meters

    FU2200A - Beijing GFUVE Electronics Co.,Ltd.

    Digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.

  • Digital Reconfigurable I/O Device

    NI

    The Digital Reconfigurable I/O (RIO) Device features user-programmable FPGA for onboard processing and flexible I/O operation. You have complete control over the synchronization and timing of all signals and operations along with custom onboard decision-making that executes with hardware-timed speed and reliability. You can configure user-defined hardware for a wide variety of applications, such as custom digital DAQ, high-speed waveform generation, sensor simulation, hardware-in-the-loop (HIL) test, custom digital communications protocols, bit error rate testing, and other applications that require precise timing and control.

  • Express Multi Protocol Board

    EXC-8000PCI - Excalibur Systems, Inc.

    The EXC-8000PCIe is a PCI Express card supporting up to eight independent 8000 family avionics communication modules, allowing multiple different protocols to be mixed and matched on a single card. Modules available include MIL-STD-1553, MIL-STD-1760, MMSI, ARINC-429, ARINC-708, ARINC-717, Serial, Discrete and CAN bus.The EXC-8000PCIe supports extensive error injection and detection capabilities, IRIG B Time Code input, and can be ordered with an extended operating temperature range of -40ºC to +85ºC and conformal coating. The EXC-8000PCIe is supplied with C drivers, including source code.

  • Combination Module: 2 Ch. MIL-STD-1553 & 12 Ch. Discrete I/O

    CM8 - North Atlantic Industries

    The CM8 module is a combination of NAI's MIL-STD-1553B module, FTB, and Enhanced Discrete I/O module, DT4. The CM8 offers twelve channels of discrete I/O and two channels of MIL-STD-1553B communications. The twelve discrete I/O channels are programmable as either input (voltage or contact sensing with programmable, on-module pull-up/pull down current sources), or output (current source, sink, or push-pull) up to 500 mA per channel from an applied, external 3-60 VCC source. The discrete I/O channels also provide additional functionality modes such as Pulse Width Modulation (PWM) output mode and Pattern Generator output mode. The two MIL-STD-1553B communications channels feature a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).

  • Compact Protocol Analyzer

    LE-1500R - LINEEYE Co., Ltd.

    "LE-1500R" is a protocol analyzer (line monitor) dedicated for asynchronous communication monitoring with affordable pricing. LE-1500R can run as a stand- alone by the internal battery for long time and can be remotely controled by a PC or a smart phone via Wi-Fi (Wi-Fi function is available only in USA, Canada, Japan, and EU). The analyzer has a TTL measurement port (which supports UART communication) as its standard port besides RS-232C, RS-422, and RS-485. It can monitor communication data of max 500Kbps for up to 32MB (8,000,000 data) in real time and also can execute a simulation testing of send/receive data. It also has a BERT function (which is not equipped with the analyzers of this pricing level) as its standard function. The correct time stamp, the measurement of idel time (which are the difficult for other software analyzers), and the capturing ability (without missing data) are the best options for trouble shooting and development test of a communication sytem which requires a reliablity.